What was found
FORWARD MOUNT SUBFLOOR CORRODED AT STATION 160 AT G1. REMOVED DAMAGE AND INSTALLED A 4 INCH BY 5 INCH DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD MOUNT SUBFLOOR CORRODED AT STATION 160 AT G1. REMOVED DAMAGE AND INSTALLED A 4 INCH BY 5 INCH DOUBLER.