What was found
STABILIZER LEADING EDGE HAS DENTS. CUT AWAY BLENDED AREA 83 INCHES FROM OUTBOARD END AND INSTALLED FLUSH REPAIR PER SRM 55-10-01-2R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STABILIZER LEADING EDGE HAS DENTS. CUT AWAY BLENDED AREA 83 INCHES FROM OUTBOARD END AND INSTALLED FLUSH REPAIR PER SRM 55-10-01-2R.