What was found
EMERGENCY EQUIPMENT COMPARTMENT HAS CORROSION ON LOWER SURFACE OF CABIN SUBFLOOR WEBBING AT STATION 190 LEFT SIDE. CORRODED SECTION OF WEBBING WAS REMOVED AND NEW SECTION DOUBLED IN ACCOMPLISHED PER AARD 53-20-00-16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EQUIPMENT COMPARTMENT HAS CORROSION ON LOWER SURFACE OF CABIN SUBFLOOR WEBBING AT STATION 190 LEFT SIDE. CORRODED SECTION OF WEBBING WAS REMOVED AND NEW SECTION DOUBLED IN ACCOMPLISHED PER AARD 53-20-00-16.