What was found
STRINGER 15 LEFT WORN FROM AIR CONDITIONING SUPPLY DUCT CONTACT AT STATION 500I. ACCOMPLISHED DOUBLER REPAIR PER SRM 53-00-03-2R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 15 LEFT WORN FROM AIR CONDITIONING SUPPLY DUCT CONTACT AT STATION 500I. ACCOMPLISHED DOUBLER REPAIR PER SRM 53-00-03-2R.