What was found
RIGHT SIDE OF AUXILIARY POWER UNIT COMPARTMENT AIR INLET ADAPTER ASSEMBLY CORRODED ON AFT FLANGE AT STRUCTURE ATTACH FLANGE. INSTALLED STIFFENER PER SRM 51-10-02-0G PARAGRAPH 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT SIDE OF AUXILIARY POWER UNIT COMPARTMENT AIR INLET ADAPTER ASSEMBLY CORRODED ON AFT FLANGE AT STRUCTURE ATTACH FLANGE. INSTALLED STIFFENER PER SRM 51-10-02-0G PARAGRAPH 8.