What was found
RIGHT CREASE BEAM CORRODED FROM STATIONS 1380 TO 1400. REMOVED AND REPLACED DITCHING PANEL PER SRM 51-10-02-G8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT CREASE BEAM CORRODED FROM STATIONS 1380 TO 1400. REMOVED AND REPLACED DITCHING PANEL PER SRM 51-10-02-G8.