What was found
DENT IN FUSELAGE STATION 1305 ABOVE LONGERON 19 RIGHT. INSTALLED TWO ROW DOUBLER AS PER BOEING DRAWING SG09530001 AND SRM 53-04-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT IN FUSELAGE STATION 1305 ABOVE LONGERON 19 RIGHT. INSTALLED TWO ROW DOUBLER AS PER BOEING DRAWING SG09530001 AND SRM 53-04-02.