What was found
CORROSION ON LOWER MOUNTING ANGLE FOR AUXULIARY POWER UNIT INLET DOOR ASSEMBLY. INSTALLED NEW ANGLE PER SRM 51-70-00-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON LOWER MOUNTING ANGLE FOR AUXULIARY POWER UNIT INLET DOOR ASSEMBLY. INSTALLED NEW ANGLE PER SRM 51-70-00-06.