What was found
CORROSION ON CREASE ANGLE AT LEFT NUMBER 2 DOOR THRESHOLD, FRAME STATIONS 690 TO 760, LEFT BUTTLINES 63 TO 65, WATERLINE 208, STRINGER 17 LEFT. REMOVED AND REPLACED CREASE ANGLE LOCATED AT FRAME STATIONS 690 TO 760, LEFT BUTTLINES 63 TO 65, WATERLINE 208, STRINGER 17 LEFT PER SRM 51-10-02-0G, PARAGRAPH 10.