What was found
FLOORBEAM STATION 947 CORRODED AT RIGHT BUTTLINE 52 TOP SURFACE. ACCOMPLISHED T-CAP REPAIR PER SRM 53-70-51-2R 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM STATION 947 CORRODED AT RIGHT BUTTLINE 52 TOP SURFACE. ACCOMPLISHED T-CAP REPAIR PER SRM 53-70-51-2R 5.