What was found
DURING INSPECTION OF AFT DECK FOUND 7 AREAS OF CORROSION AT STATIONS 1681 TO 1718, RIGHT BUTTLINES 6 TO 47. INSTALLED DOUBLER AND SPLICE PER EA B757-53-014322 DATED 12/6/2010, SRM 53-60-51-3 AND SRM 53-60-51-2R-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION OF AFT DECK FOUND 7 AREAS OF CORROSION AT STATIONS 1681 TO 1718, RIGHT BUTTLINES 6 TO 47. INSTALLED DOUBLER AND SPLICE PER EA B757-53-014322 DATED 12/6/2010, SRM 53-60-51-3 AND SRM 53-60-51-2R-2.