FOUND TWO LOOSE BUSHINGS ON CARRIER BEAM ON THE RIGHT OUTBOARD FLAP NUMBER 1 SUPPORT. FOUND OUT-OF-ROUND CONDITION MEASURED HOLE DIAMETERS DIFERED BY A MAX OF 0.002" REAMED THE SUBJECT HOLES ON-CENTER UP TO (1.612") TO CORRECT THE CONDITION. PERFORMED SURFACE HFEC AND NO CRACKS FOUND. ROTO-PEENED THE HOLES PER SRM USING A 0.10A INTENSITY AND COVERAGE OF 2.0. HONED THE LUGS AND INSTALLED OVERSIZED BUSHING PER BAC DRAWING 113T1347 AND MAJOR EA COMP-57-014977.