What was found
FOUND CRACK TO RIGHT SIDE STATION 1809.5 TENSION FITTING PER SB 767-53A0078. BOTH HOLES WERE OVERSIZED TO 0.2755 INCH IN ORDER TO REMOVE CRACK INDICATIONS PER MAJOR EA B767-53-016071.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.