What was found
OUTBOARD OF LEFT SIDEWALL PANEL LAVATORY SERVICE BOX DAMAGED FORWARD EDGE AT WATER HOSE ATTACH POINT FLANGE SEPARATED ON OUTER SURFACE OF BOX. INSTALLED DOUBLER PER SRM 51-40-02-0G AND EA B757-53-016940 DATED 17-MAY-2011.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OUTBOARD OF LEFT SIDEWALL PANEL LAVATORY SERVICE BOX DAMAGED FORWARD EDGE AT WATER HOSE ATTACH POINT FLANGE SEPARATED ON OUTER SURFACE OF BOX. INSTALLED DOUBLER PER SRM 51-40-02-0G AND EA B757-53-016940 DATED 17-MAY-2011.