What was found
CRACK IN SKIN AT STATION 1475 CANT FRAME. STOP DRILLED ENDS OF CRACK AND INSTALLED EXTERNAL DOUBLER PER SRM 53-01-00 FIGURE 2 SHEET 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK IN SKIN AT STATION 1475 CANT FRAME. STOP DRILLED ENDS OF CRACK AND INSTALLED EXTERNAL DOUBLER PER SRM 53-01-00 FIGURE 2 SHEET 3.