What was found
CORROSION ON U-CHANNEL IN THRESHOLD OF RIGHT NUMBER 1 ENTRY DOOR, FRAME STATIONS 324 TO 377. INSTALLED NEW U-CHANNEL AT THE RIGHT NUMBER 1 SERVICE/PASSENGER DOOR PER SRM 51-109-02-0G, AND AARD 51-00-05-1, REPAIR 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON U-CHANNEL IN THRESHOLD OF RIGHT NUMBER 1 ENTRY DOOR, FRAME STATIONS 324 TO 377. INSTALLED NEW U-CHANNEL AT THE RIGHT NUMBER 1 SERVICE/PASSENGER DOOR PER SRM 51-109-02-0G, AND AARD 51-00-05-1, REPAIR 1.