What was found
MAIN CABIN FLOOR SUPPORT ANGLE AND SILL SUPPORT STRUCTURE CORRODED UNDER DRAIN PLATE FROM BODY STATIONS 676 TO 740, LEFT BUTTLINES 61 TO 64. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT SILL PER BAC DWG 143N8322.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR SUPPORT ANGLE AND SILL SUPPORT STRUCTURE CORRODED UNDER DRAIN PLATE FROM BODY STATIONS 676 TO 740, LEFT BUTTLINES 61 TO 64. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT SILL PER BAC DWG 143N8322.