What was found
LONGERON 2 RIGHT CRACKED AFT OF STATION 1418. INSTALLED LONGERON SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LONGERON 2 RIGHT CRACKED AFT OF STATION 1418. INSTALLED LONGERON SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.