What was found
CREASE BEAM ANGLE HAS A CRACK AT FASTENER HOLE, IN THE RADIUS, AND 2 CRACKS ABOVE AND BELOW HORIZONTAL FASTENER HOLE AT STATION 302 LEFT BUTTLINE 55. REMOVED AND REPLACED CREASE ANGLE STRUCTURE FROM STATIONS 290 TO 357, LEFT BUTTLINE 55 PER SRM 51-40-02. A MINOR EA WAS ACCOMPLISHED (EA B737-53-024560) ON FILLING MISDRILLED NUT PLATE HOLES FROM FACTORY AT 5 EACH FASTENER LOCATIONS.