CORROSION ON T-CAP OF FLOORBEAM AT STATION 1660. ACCOMPLISHED NESTED ANGLE REPAIR PER SRM 53-00-51-2R 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON T-CAP OF FLOORBEAM AT STATION 1660. ACCOMPLISHED NESTED ANGLE REPAIR PER SRM 53-00-51-2R 3.