What was found
CORROSION ON FLOORBEAM AT STATION 347 RIGHT BUTTLINES 30 TO 52. REMOVED DAMAGED AREA OF FLOORBEAM CAP AND REPAIRED PER SRM 53-00-51-2R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT STATION 347 RIGHT BUTTLINES 30 TO 52. REMOVED DAMAGED AREA OF FLOORBEAM CAP AND REPAIRED PER SRM 53-00-51-2R.