What was found
CORROSION ON LAP SEAM, STATION 1241 AT STRINGER 36 LEFT. CUT OUT DAMAGE AND INSTALLED EXTERNAL DOUBLER PER SRM 53-00-01-2R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON LAP SEAM, STATION 1241 AT STRINGER 36 LEFT. CUT OUT DAMAGE AND INSTALLED EXTERNAL DOUBLER PER SRM 53-00-01-2R.