What was found
STATIC BURN FOUND AT STATION 266, LONGERON 7 RIGHT. INSTALLED INTERNAL REPAIR DOUBLER AND SKIN PLUG AS PER SRM 53-04-02 FIGURE 2, SHEET 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATIC BURN FOUND AT STATION 266, LONGERON 7 RIGHT. INSTALLED INTERNAL REPAIR DOUBLER AND SKIN PLUG AS PER SRM 53-04-02 FIGURE 2, SHEET 6.