What was found
VERTICAL STIFFENER CORRODED AT STATION 1126, AT AUXILIARY POWER UNIT AIR INLET. REPLACED VERTICAL STIFFENER PER AARD 51-10-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERTICAL STIFFENER CORRODED AT STATION 1126, AT AUXILIARY POWER UNIT AIR INLET. REPLACED VERTICAL STIFFENER PER AARD 51-10-05.