As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AUXILIARY POWER UNIT COMPARTMENT, RIGHT HORIZONTAL STIFFENER AT BOTTOM OF INLET CUTOUT IS CORRODED AT AFT FASTENER HOLES FOR TORQUE BOX FLOOR PANEL ATTACH. REMOVED CORRODED STIFFENER AND INSTALLED HORIZONTAL STIFFENER AT BOTTOM OF APU INLET PER AARD 51-10-05-1 AND BOEING DRAWING 148A8650.