What was found
FLOOR STRUCTURE INTERCOSTAL BETWEEN BS 927 AND 947 AND LBL 51 IS CORRODED ON TOP PLATE, AFT END. INSTALLED NEW INTERCOSTAL IAW RD 51-00-05-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR STRUCTURE INTERCOSTAL BETWEEN BS 927 AND 947 AND LBL 51 IS CORRODED ON TOP PLATE, AFT END. INSTALLED NEW INTERCOSTAL IAW RD 51-00-05-1.