What was found
CRACKED FLOOR SUPPORT FROM BS 312 TO 328, RBL 30.5 AND WL 208. REPLACED FLOOR SUPPORT IAW RD 51-10-05-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR SUPPORT FROM BS 312 TO 328, RBL 30.5 AND WL 208. REPLACED FLOOR SUPPORT IAW RD 51-10-05-1.