What was found
HEAVY CORROSION ON CREASE ANGLE & ATTACHED FLOOR BOARD SUPPORT AT DOOR THRESHOLD AT RT HAND AFT SERVICE DOOR FROM STATIONS 967 TO 992. INSTALLED CREASE ANGLE IAW AARD 51-10-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HEAVY CORROSION ON CREASE ANGLE & ATTACHED FLOOR BOARD SUPPORT AT DOOR THRESHOLD AT RT HAND AFT SERVICE DOOR FROM STATIONS 967 TO 992. INSTALLED CREASE ANGLE IAW AARD 51-10-05.