Service difficulty report · Duct · Doug DC983

Difficulty date
November 6, 2013
Submitted
November 22, 2013
Operation
Air carrier
Aircraft
N9681B
Make and model
Doug DC983
Aircraft serial
53631
Aircraft time
39,566 hours, 19,314 cycles
Part
Duct
Part number
ADK59491
Condition
Blown
Location
Anti-Ice Sys
Stage of operation
CL
How discovered
O
Nature of condition
M, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TPA INFLIGHT JAX-DFW. INTERMITTENT FIRE INDICATIONS ON LT ENGINE. BRINGING LT THROTTLE BACK SILENCED WARNING. EMERGENCY DECLARED FLIGHT DIVERTED TPA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RUPTURED LT COWL ANTI ICING DUCT. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSED.