FUSELAGE SKIN CRACKED AT FASTENER STATION 1418 BETWEEN LONGERONS 2 & 3 RT. INSTALLED FILLER INTERNAL & EXTERNAL DOUBLER IAW SRM 53-04-00 FIGURE 40 SHEET 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE SKIN CRACKED AT FASTENER STATION 1418 BETWEEN LONGERONS 2 & 3 RT. INSTALLED FILLER INTERNAL & EXTERNAL DOUBLER IAW SRM 53-04-00 FIGURE 40 SHEET 1.