What was found
FWD SUBFLOOR, G2 GALLEY, INBD AFT FLOOR MOUNT HAS CORROSION AT STATION 218. INSTALLED G-2 GALLEY MOUNT FITTING IAW AARD 51-00-05-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD SUBFLOOR, G2 GALLEY, INBD AFT FLOOR MOUNT HAS CORROSION AT STATION 218. INSTALLED G-2 GALLEY MOUNT FITTING IAW AARD 51-00-05-1.