What was found
STATION 1680 AT LBL 12 T CAP HAS CORROSION UNDER METAL CLIP. FLOORBEAM FOUND TO BE OUT OF LIMITS AFTER CORROSION REMOVED. REPAIRED FLOORBEAM IAW SRM 53-60-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 1680 AT LBL 12 T CAP HAS CORROSION UNDER METAL CLIP. FLOORBEAM FOUND TO BE OUT OF LIMITS AFTER CORROSION REMOVED. REPAIRED FLOORBEAM IAW SRM 53-60-51.