What was found
SEVEN LOOSE FASTENERS FOUND ON DETAILED INSPECTION OF VERTICAL STAB LE AT STATION ZFS 52.267 BELOW THE SPLICE. REMOVED EXISTING SMALL DOUBLER & FOUND 18 1/4 FASTENER & 11 3/16 FASTENER HOLES TO BE ELONGATED. INCREASED DIAMETER OF HOLES & INSTALLED STRAIGHT SLUG BUSHINGS IN HOLES. INSTALLED NEW LARGER DOUBLER OVER REPAIRED HOLES IAW SRM 55-03-00 & DWG SGO9550004.