What was found
THREE LOOSE FASTENERS FOUND ON DETAILED INSPECTION OF VERTICAL STAB LE AT STATION ZFS 52.267 ABOVE THE SPLICE. FURTHER INSPECTION FOUND 7 EXISTING FASTENER HOLES WITH REPAIR COUNTERSUNK BUSHINGS INSTALLED & 14 ADDITIONAL FASTENER HOLES THAT WERE ELONGATED. ENLARGED 14 1/4 FASTENER & 3 3/16 FASTENER HOLES FOR REPAIR COUNTERSUNK BUSHINGS. INSTALLED REPAIR COUNTERSUNK BUSHINGS IN HOLES IAW SRM 55-03-00-001.