What was found
SUBFLOOR SUPPORT ANGLE CRACKED AT STATION 185 & RBL 26, BOTTOM SIDE OF SUBFLOOR. REMOVED CRACKED ANGLE & INSTALLED NEW SERVICEABLE FABRICATED ANGLE IAW SRMS 51-00-00-1, 51-10-09 & DWG 9936534.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SUBFLOOR SUPPORT ANGLE CRACKED AT STATION 185 & RBL 26, BOTTOM SIDE OF SUBFLOOR. REMOVED CRACKED ANGLE & INSTALLED NEW SERVICEABLE FABRICATED ANGLE IAW SRMS 51-00-00-1, 51-10-09 & DWG 9936534.