What was found
R3 DOOR EMER POWER ASSIST SYS FAILED BATTERY OPERATIONAL TEST. REPLACED MODE SELECT SWITCH ON R3 DOOR IAW AMM 52-11-28. SYSTEMS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R3 DOOR EMER POWER ASSIST SYS FAILED BATTERY OPERATIONAL TEST. REPLACED MODE SELECT SWITCH ON R3 DOOR IAW AMM 52-11-28. SYSTEMS CHECKED NORMAL.