What was found
FORWARD AIRSTAIRS SUPPORT ANGLE IS CRACKED AT THE TOP FASTENER, FUSELAGE STATION 160 LT JUST INSIDE STAIR ACCESS DOOR. CRACK IS 3 INCHES LONG FROM BOTTOM OF FASTENER HOLE. R & R SUPPORT ANGLE IAW SRM 51-00-05-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD AIRSTAIRS SUPPORT ANGLE IS CRACKED AT THE TOP FASTENER, FUSELAGE STATION 160 LT JUST INSIDE STAIR ACCESS DOOR. CRACK IS 3 INCHES LONG FROM BOTTOM OF FASTENER HOLE. R & R SUPPORT ANGLE IAW SRM 51-00-05-1.