What was found
RETURNED & EMER DECLARED. LANDING UNEVENTFUL. ACFT NOT OVERWEIGHT. DURING CLIMB, AT 10000 FEET, FLIGHT ATTENDANT REPORTED NO AFT GALLEY POWER. CYCLED CABIN UTILITY BUS & BUS SWITCH WOULD NOT RESET. FLIGHT ATTENDANT REPORTED CABIN TEMPERATURE CONTROL FLUCTUATED, VERY COLD THEN VERY HOT. ACCOMPLISHED FIM 26-14-00-810. RESET AIRFLOW & SMOKE SWITCH & CABIN UTILITY BUS SWITCH. OPERATION & INDICATIONS OF AFT GALLEY POWER & CABIN TEMP CONTROL NORMAL.