What was found
EMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING APPROACH WHILE EXTENDING FLAPS TO 15 FOR LANDING NOTED FLAP ASYMMETRY NEEDLES STUCK AT 7 DEGREES & 9 DEGREES WITH FLAPS TRANSIT AMBER LIGHT ON. LE DEVICE ANNUNCIATORS ALL GREEN. ACCOMPLISHED FIM 27-51-00-810-832 BITE CHECK OF FSEU WITH NO FAULTS NOTED. ACCOMPLISHED CHECK OF LT & RT FLAP SYNCHRO RESOLVERS IAW AMM 27-51-00-730-801. SETTINGS CHECKED WITHIN LIMITS IAW TABLE 502. R & R THE FSEU PRECAUTIONARY IAW AMM 27-51-01. SYS CHECKED NORMAL.