As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING DESCENT HYD PUMPS WERE PLACED TO HIGH, RT HYD PRESS DROPPED & RUDDER CONTROL MANUAL LIGHT ILLUMINATED. ALL QRH PROCEDURES COMPLIED WITH & ALTERNATE GEAR EXTENSION ACCOMPLISHED. R & R NR 2 ENG HYD PUMP IAW AMM 29-10-05 & RT HYD SYS RESERVOIR IAW AMM 29-10-01. PERFORMED OPERATIONAL & LEAK CHECKS. SYS CHECKED NORMAL.