What was found
SEVERE LIGHTNING STRIKE STATIC BURNS ON FS SKIN AT STATION 345 BETWEEN LONGERON 26R & 27R IS OUT OF LIMITS. REMOVED DAMAGE & INSTALLED REPAIR DOUBLE IAW SRM 53-04-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEVERE LIGHTNING STRIKE STATIC BURNS ON FS SKIN AT STATION 345 BETWEEN LONGERON 26R & 27R IS OUT OF LIMITS. REMOVED DAMAGE & INSTALLED REPAIR DOUBLE IAW SRM 53-04-03.