What was found
EMERGENCY DECLARED & LANDING UNEVENTFUL. ACFT NOT OVERWEIGHT. DURING APPROACH FLAPS EXTENDED TO 5 ONLY WITH FLAP HANDLE SELECTED TO 10. PERFORMED FLAP & SLAT CONTROL SYS TEST IAW AMM 27-81-00. FLAP & SLAT TIMING TEST IN PRIMARY MODE IAW AMM 27-81-00. FLAP & SLAT POSITION INDICATION SYS TEST IAW AMM 27-88-00. DFCS SENSOR TEST IAW AMM 22-11-00. FSEU BITE IAW AMM 27-51-00. VISUAL INSPECTION IAW AMM 27-51-00-210 WITH NO FAULTS OR DEFECTS FOUND. SYS CHECKED NORMAL.