What was found
RIGHT FLOOR CUSP CRACKED IN 2 PLACES BETWEEN FS 1287 & 1309. R & R RT FLOOR CUSP SECTION BETWEEN FS 1250 - 1309 IAW AARD 51-00-05-1 & DWG 9930612.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT FLOOR CUSP CRACKED IN 2 PLACES BETWEEN FS 1287 & 1309. R & R RT FLOOR CUSP SECTION BETWEEN FS 1250 - 1309 IAW AARD 51-00-05-1 & DWG 9930612.