What was found
BULK CARGO DOOR CUT OUT AREA, CORROSION ON LONGITUDINAL FLOOR SUPPORT FRAME TAPERED SPLICE UNDER FLOOR AT STATION 1417 & LBL 44. R & R TAPERED SPLICE IAW SRM 51-40-02, 51-10-02 & DWG 146T8210 SHEET 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BULK CARGO DOOR CUT OUT AREA, CORROSION ON LONGITUDINAL FLOOR SUPPORT FRAME TAPERED SPLICE UNDER FLOOR AT STATION 1417 & LBL 44. R & R TAPERED SPLICE IAW SRM 51-40-02, 51-10-02 & DWG 146T8210 SHEET 2.