What was found
C4 CHECK, FLOORBOARD SUPPORT ANGLE CRACKED BETWEEN STATION 780 & 800 AT BL 0. FABRICATED & INSTALLED NEW ANGLE IAW DWG 143N5140.040 7075 T6 FROM BAC1493-412.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK, FLOORBOARD SUPPORT ANGLE CRACKED BETWEEN STATION 780 & 800 AT BL 0. FABRICATED & INSTALLED NEW ANGLE IAW DWG 143N5140.040 7075 T6 FROM BAC1493-412.