What was found
C1 CHECK, CORROSION ON FWD CARGO COMPARTMENT FLOOR SUPPORT SIDE PANEL TIE DOWN FITTING BETWEEN STATION 640 & 840 AT RBL 22.50. REPLACED TIE DOWN FITTING IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C1 CHECK, CORROSION ON FWD CARGO COMPARTMENT FLOOR SUPPORT SIDE PANEL TIE DOWN FITTING BETWEEN STATION 640 & 840 AT RBL 22.50. REPLACED TIE DOWN FITTING IAW SRM 51-40-02.