What was found
CABIN FLOOR SUPPORT INTERCOSTAL CRACKED AT CTR CLIP NUT HOLE AT LBL 46 BETWEEN STATIONS 312 & 328 FLOORBEAMS. R & R SUPPORT IAW AARD 51-00-05-1 & DWG 141A5400.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR SUPPORT INTERCOSTAL CRACKED AT CTR CLIP NUT HOLE AT LBL 46 BETWEEN STATIONS 312 & 328 FLOORBEAMS. R & R SUPPORT IAW AARD 51-00-05-1 & DWG 141A5400.