What was found
EMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING APPROACH, TE FLAP DISAGREE LIGHT ILLUMINATED WHEN FLAP HANDLE MOVED FROM UP TO 1 DETENT. R & R RT WING FLAP TRANSMISSIONS NR 4 & 8 IAW 27-51-17, LT WING INBD FLAP TRANSMISSION IAW 27-51-06 & LT WING FLAP POSITION TRANSMITTER IAW 27-58-03. PERFORMED OPERATIONAL & CHECKS. SYS CHECKED NORMAL. SEE ALSO AALA20150529008, AALA20150601007 & AALA20150601009.