WHILE PERFORMING SQUIB TEST 2, LT & RT OVERWING SQUIBS ILLUMINATE INTERMITTENTLY. R & R SQUIB TEST PANEL. PERFORMED OPERATIONAL CHECK IAW AMM 26-21-04. SYS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE PERFORMING SQUIB TEST 2, LT & RT OVERWING SQUIBS ILLUMINATE INTERMITTENTLY. R & R SQUIB TEST PANEL. PERFORMED OPERATIONAL CHECK IAW AMM 26-21-04. SYS CHECKED NORMAL.