What was found
AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB RETRACTED FLAPS & RT FLAPS STAYED AT FLAPS 6. R & R RT INSTRUMENT TRANSFORMER T1-20 & B1-116 CB IAW WDM 24-54-00. PERFORMED OPERATIONAL CHECK OF FLAPS. SYS CHECKED NORMAL. SEE ALSO AALA20150714009.